Avaya DEFINITY Server CSI Maintenance Manual page 982

Table of Contents

Advertisement

Audit Update Test (#36)
This audit makes sure that the hardware state of the Data Line is consistent with
the system translations. When this audit is run, the port is queried for the
switchhook state, and the software state is updated according to the returned
value. Also, the data line options are sent down to the port.
Table 182. TEST #36 Audit Update Test
Error
Test
Code
Result
1000
ABORT
1006
ABORT
2000
ABORT
2100
ABORT
7
FAIL
PASS
982
Issue 5 October 2002
Description/ Recommendation
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. Escalate the problem if the test continues to abort.
The test did not run due to an already existing error on this port (Error Type
769).
1. Refer to the procedure for Error Type 769. If Error Type 769 still occurs
on this port, replace the circuit pack.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
The hardware port state is consistent with the software state. User-reported
troubles on this port should be investigated using other port tests, examining
the ADU, external wiring, and customer equipment.
Continued on next page
555-233-119