Table 203. TEST #1201 Digital Terminal Remote Loop Around Test — Continued
Error
Test
Code
Result
1004
ABORT
1005
ABORT
2000
ABORT
2100
ABORT
14
FAIL
1015
ABORT
1034
Issue 5 October 2002
Description/ Recommendation
The port was seized by a valid call during the test. The test has been
aborted. Use display port PCSSpp to determine the station extension or
attendant number of the port. Use status station or status attendant to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain test. You must wait
until the port is idle before resetting. Attendants are always in use (off-hook)
if the handset is plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The installed circuit pack does not support this operation.
Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test are not available.
1. Make sure terminal is connected and repeat test.
2. If test fails replace terminal and repeat test.
3. Retry the command at 1-minute intervals a maximum of 5 times.
The primary channel (voice, Information Channel 1 or I1) is not operating
properly. User impact may range from noticing nothing to not being able to
use the port. Check the results of Voice and Control Channel Local Loop
Test (#13). If that test fails, suspect the Digital Line circuit pack. If that test
passes then replace the terminal. If both tests fail and component
replacement does not change the results, then:
1. Run circuit pack tests to check the tone generator circuit pack and the
Tone Detector circuit pack using the test board PCSSpp command.
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit pack are functioning
properly, and the tests still fail, escalate the problem.
The system will not allow this test to be run because the station is/has not