Maintenance Objects
Table 103. ATM Board Framer Looparound Test (#1260) — Continued
Error
Test
Code
Result
Description/Recommendation
5
FAIL
Unable to create packet-path loop.
Retry the command up to 3 times at 1-minute intervals.
If this test continues to fail, replace the ATM-TRK circuit pack.
Rerun test board UUCSS long.
6
FAIL
A previously established looparound was not released.
Run reset board UUCSS.
Retry the command up to 3 times at 1-minute intervals.
If this test continues to fail, replace the ATM-TRK circuit pack.
Rerun test board UUCSS long.
PASS
The non-optical parts of the ATM-TRK circuit pack are functioning properly.
0
NO
ATM-TRK circuit pack not found
BOARD
Check the error log for Error 125 (wrong board) or Error 131 (no board), and
correct as necessary.
Check that the board is properly translated and inserted.
Check for Error 1538 (hyperactivity), and run reset board UUCSS if
necessary.
Rerun test board UUCSS long.
If the test fails, replace the board, and rerun test board UUCSS long.
ATM Board Time Of Day Update (#1261)
The nondestructive ATM-TOD-UPD test updates the system time that the
ATM-TRK circuit pack uses for SDH/SONET performance monitoring and
synchronizes the ATM-TRK circuit pack with the Avaya Definity Server CSI
system clock. This test is run during initialization, scheduled maintenance, and
craft long test.
782
Issue 5 October 2002
Continued on next page
555-233-119