TIE-DS1 (DS1 Tie Trunk)
Table 499. TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error
Test
Code
Result
0
NO
BOARD
1.
Earlier G1 Software Versions reported Error Code 2053's Test Result as FAIL.
555-233-119
Description/ Recommendation
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
check to see that there is a valid board inserted.
Continued on next page