HYB-LINE (Hybrid Line)
Hybrid Line Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status
record contained in the processor. The lamp updates run only if the station is
in-service.
Table 293. TEST #60 Hybrid Line Lamp Updates Test
Error
Test
Code
Result
1
ABORT
2
ABORT
3
ABORT
1000
ABORT
FAIL
PASS
555-233-119
Description/ Recommendation
A request for a remote station lamp update aborted even though all internal
resources were correctly allocated.
1. Look in the error log for error type 18 (port busied out) for this port. If
this error type is present, release the port via the release port PCSSpp
command or the release station extension command, and then run
the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
The station is in a ready for service or an out of service state. This may be
due to wiring or an unplugged or defective set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension number of the port. Use the status station
command to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain tests.
You must wait until the port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Hybrid Line Lamp Updates completed successfully.
1. If complaints still exist, investigate by using other circuit pack tests, and
by examining the station, wiring, and connections.
Continued on next page
Issue 5 October 2002
1253