CLAN-BD (Control LAN Circuit Pack)
Table 148. TEST #600 Congestion Query Test
Error
Test
Code
Result
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
2012
ABORT
Could not allocate the necessary system resources to run test.
2100
ABORT
Internal system error.
1
FAIL
The buffer level is nearly exhausted.
2
FAIL
The CLAN is congested, and no buffers are available.
Low processor occupancy when CLAN congested indicates circuit pack
failure.
High processor occupancy indicates the CLAN is congested due to traffic
load.
3
FAIL
The CLAN circuit pack is not operating normally and is congested.
PASS
Hardware setting and attached cable type match CLAN circuit pack
administration. The circuit pack detects no errors.
555-233-119
Description/ Recommendation
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1. Retry command at 1-minute intervals, up to 5 times.
2. If command continues to fail, examine the CLAN port measurements to
determine which ports are heavily utilized and the processor occupancy
of the circuit pack.
1. If the problem persists, reset the circuit pack (reset board UUCSS).
2. If congestion recurs, replace the circuit pack.
1. To relieve congestion in the short term, selectively busyout ports
(busyout port UUcSSpp) on the Control LAN circuit pack.
2. To achieve a more permanent resolution, it may be necessary to move
ports on this circuit pack to other Control LAN circuit packs.
3. Consider replacing affected CLAN ports with new ports.
Continued on next page