CLAN-BD (Control LAN Circuit Pack)
k. Error Type 2049: Packet Interface Test (#598) failed.
1. Attempt to clear the alarm (test board UUCSS l r 3).
2. If alarm does not clear, reset the circuit pack (reset board UUCSS).
3. If circuit pack resets, execute Packet Interface Test (#598) several
4. If Packet Interface Test (#598) continues to fail, replace the circuit
l. Error Type 2305-2306: Error in received frame from packet bus.
Error Type:
2305
2306
Most likely cause—packet bus problem.
Other cause—circuit pack fault.
Invalid LAPD frame errors occur when the frame
1. Retry the command (test board UUCSS) and see if the condition
2. If condition persists, execute PPE/LANBIC Receive Parity Error
3. If condition persists, execute Packet Interface Test (# 598) to verify
4. If Packet Interface Test (# 598) fails, consult repair procedure for the
m. Error Type 2561-2668: System software received an indication that the
socket was closed due to an error. Errors are reported as log only. Errors
logged here are for the sockets that had no processor channels associated
with them, for example, sockets to read SNMP data. The counter base is
offset by the application type of the application associated with this socket
that is down. The Aux Data field of the log entry contains this application's
number, for example, a SNMP application would have its application
number in the Aux Data field.
555-233-119
times.
pack.
Description
Received invalid LAPD frame.
Detected parity error on received frame.
contains a bad Cyclic Redundancy Check (CRC),
is greater than the maximum length,
violates the link level protocol.
clears.
Counter Test (# 597) and determine if the condition clears.
circuit pack integrity.
packet bus.
NOTE:
2561 - 2668 is a range of reserved numbers for future applications.
2570 currently represents an SNMP socket failure.
Issue 5 October 2002
879