Table 112. TEST #619 BRI Port Local TDM Loop Around — Continued
Error
Test
Code
Result
1003
ABORT
1004
ABORT
1005
ABORT
2000
ABORT
2012
ABORT
2100
ABORT
2103
ABORT
1, 2
FAIL
555-233-119
Description/ Recommendation
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
(TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
(Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
The port has been seized by a user for a valid call. Use the status station
command for the station associated with this port and determine when the
port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
This test is not valid for this type of translation. Ports administered as
"ASAI" or "ADJK" can not run this test, because the B channels associated
with the port are not used by ASAI or Adjunct Links. This is a normal
condition.
Response to the test was not received from the BRI-LINE circuit pack
within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the
other ports are not in use. Reset the circuit pack by issuing the
busyout board PCSS and the reset board PCSS commands.
2. If this result occurs again, replace the circuit pack.
Internal system error.
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
As stated previously, this test runs a TDM Loop Around Test on each
B-channel. This indicates that the loop around failed on one of the
channels. Error Code 1 indicates that the TDM Loop Around Test failed on
B1. Error Code 2 indicates that the TDM Loop Around Test failed on B2.