Table 288. TEST #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
1004
ABORT
1018
ABORT
2000
ABORT
2020
ABORT
2100
ABORT
Any
FAIL
PASS
1242
Issue 5 October 2002
Description/ Recommendation
The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Test disabled via administration. This only applies to analog stations. The
default for this field is 'y,' so you may want to determine why it has been
turned off for this station.
1. To enable test, set the
for the particular analog station being tested to y. Use the change
station <extension> command.
Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
This test can fail due to on-board or off-board problems. Off-board
problems of concern include EXP-INTF faults, TDM-BUS faults, and faults
associated with the tone detectors/tone generators. Clear all off-board
problems before replacing the board. Keep in mind that a TDM-BUS
problem is usually the result of a faulty board connected to the backplane
or bent pins on the backplane.
1. Look for EXP-INTF errors in the error log. If present, refer to the
EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer to the
TDM-BUS Maintenance documentation.
3. Retest the board when the faults from steps 1 and 2 are cleared.
The port is correctly using its allocated time slots. User-reported troubles
on this port should be investigated using other port tests and examining
station, trunk, or external wiring.
field on the station administration screen
Test
Continued on next page
555-233-119