Maintenance Objects
When this error occurs for an ASAI or adjunct, the Aux Data field indicates
the state of the ASAI link or link and whether an invalid response or no
response was received to the query from the switch, as shown in
121:
Table 121. ASAI Link State
Aux Data
ASAI Link State
102
13-restarting
104
13-restarting
152
13-restarted
154
13-restarted
202
13-established
204
13-established
(See
explanation of the ASAI link states.)
For ASAI or adjuncts, the switch automatically queries the adjunct every
two minutes. The Layer 3 Query Test is not executed for ASAI or adjuncts
via a command issued from the G3MT terminal. While alarmed for this
error, the switch takes the associated port out-of-service for 5 seconds
every 15 minutes. This is an attempt to stimulate recovery actions taken by
the adjunct.
When this error occurs for an ASAI or adjunct, the service technician
should:
1. Use test station extension, note any tests that fail, and perform the
2. Check the health of the adjunct by following the recommended
3. Follow normal escalation procedures if the above steps do not
d. This error and associated WARNING alarm are logged against an ASAI or
endpoint when the adjunct has asked the switch to suspend Maintenance
on the ASAI or endpoint. Busying out and releasing the ASAI station or
ADJLK station will clear this alarm.
e. This error occurs when the endpoint sends more messages than the switch
can handle. The switch suspends the reception of messages from the
endpoint for a short period of time. There is no repair procedure for this
error. If the condition persists, replace the endpoint.
824
Issue 5 October 2002
No response to RESTART message
Invalid response to RESTART message
No response to Layer 3 query
Invalid response to Layer 3 query
No response to Layer 3 query
Invalid response to Layer 3 query
''status bri-port''
in
Chapter 2, ''Maintenance Commands''
associated repair procedures for those tests.
repair procedures of the manufacturer of the adjunct.
resolve the problem.
Error
Continued on next page