Avaya DEFINITY Server CSI Maintenance Manual page 1005

Table of Contents

Advertisement

DID-TRK (DID Trunk)
Table 189. TEST #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
1004
ABORT
2000
ABORT
2100
ABORT
Any
FAIL
PASS
555-233-119
Description/ Recommendation
The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension, attendant number, or trunk group/member number of the port.
Use the status station, status attendant, or status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting. Attendants are always in use (off-hook)
if the handset is plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
This test can fail due to on-board or off-board problems. Off-board
problems of concern include EXP-INTF faults, TDM-BUS faults, and faults
associated with the tone detectors/tone generators. Clear all off-board
problems before replacing the board. Keep in mind that a TDM-BUS
problem is usually the result of a faulty board connected to the backplane or
bent pins on the backplane.
1. Look for EXP-INTF errors in the error log. If present, refer to the
EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer to the
TDM-BUS Maintenance documentation.
3. Look for TONE-BD and/or TONE-PT errors in the error log. If present,
refer to the TONE-BD Maintenance documentation and the TONE-PT
Maintenance documentation.
4. Test the board when the faults from steps 1, 2, and 3 are cleared.
Replace the board only if the test fails.
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and by examining
station, trunk, or external wiring.
Continued on next page
Issue 5 October 2002
1005

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents