E-DIG-STA (Emulated Digital Line)
Table 250. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Test
Code
Result
2000
ABORT
2100
ABORT
7
FAIL
14
FAIL
15
FAIL
16
FAIL
PASS
555-233-119
Description/ Recommendation
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Rerun the test at 1-minute intervals a maximum of 5 times.
Conference Test failed on primary channel. In some cases, users may not
notice disruption in service. In extreme cases, conferencing feature may
not work at all.
The primary voice channel is not transmitting properly. User impact may
range from noticing nothing to not being able to use this port.
The control channel between the processor and digital circuit pack is not
transmitting properly. User impact may range from noticing nothing to not
being able to use the port. This could disrupt other users.
The secondary voice channel is not transmitting properly. User impact may
range from noticing nothing to not being able to use this port.
1. Run circuit pack tests to check the Tone Generator circuit pack and the
Tone Detector circuit pack using the test board PCSSpp command.
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly and the test still fails, replace the Digital Line circuit pack.
The test passed, and all channels are transmitting properly.
1. To ensure that this is not an intermittent problem, repeat this test up to
10 times.
2. If noisy connections for voice or corrupted data for data transfer
persist, examine the station, connections, and wiring.