Avaya DEFINITY Server CSI Maintenance Manual page 1028

Table of Contents

Advertisement

Status of Parameter Downloads
The "status station" and "status attendant" screens display the current download
status of individual 84xx, 603, and 301B1 terminals in the Download Status field.
The possible download states are:
Table 200. Terminal Download Status
Status
Complete
Pending
Not Applicable
Possible reasons for terminal being not downloaded include:
— Terminal is off-hook.
— Terminal detected a bad checksum.
— Terminal detected a bad or missing EEPROM (refer to hardware error log).
— Terminal is busy programming data from a previous PROGRAM message.
— Terminal is in the Programming Disabled state.
— Terminal is in the Local Program Options Mode.
— Terminal is disconnected or out of service (use status station command).
Hardware Error Log Entries and Test to Clear
Values
Table 201. DIG-LINE Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1 (a)
40987
None
1 (b)
1 to 20
None
18 (c)
0
busyout port
PCSSpp
130 (d)
None
1028
Issue 5 October 2002
Terminal successfully downloaded sometime in the past.
System waiting to download the terminal. This may require the
execution of a background periodic test which could take more than
an hour. A demand download as described above may also be
used to initiate an immediate download.
Not a programmable terminal.
Associated Test
Alarm Level
Any
WARNING
WARNING
WARNING
WARNING
Terminal Down Load State
On/Off
Board
Any
test port PCSSpp sh r 1
OFF
OFF
OFF
rel port PCSSpp
ON
test port PCSSpp sh
Test to Clear Value
Continued on next page
555-233-119

Hide quick links: