Maintenance Objects
Table 370. TEST #1111 Resource Looparound Test
Error
Test
Code
Result
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1002
ABORT
The system could not allocate time slots for the test. The traffic load on the
system may be very high or time slots may be out-of-service due to TDM-Bus
errors. Refer to
errors.
1003
ABORT
The system could not allocate a tone detector for the test. The system is
oversized for the number of tone detectors present or some tone detectors
are out-of-service.
1004
ABORT
The resource has been seized by a user for a valid call. Use the status
conference command to verify that there is a conference call active.
2000
ABORT
Response to the test was not received from the Tone Detector circuit pack
within the allowable time period.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary resources to run this test. Abnormal abort.
1412
Issue 5 October 2002
Description/Recommendation
1. Retry the command at 1-minute intervals a maximum of five times.
2. Use the status conference command to determine if there is an active
conference. If a call is active, the test cannot be run until the conference
call terminates.
''TDM-BUS (TDM Bus)''
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals a maximum of five times.
1. Resolve any
''TTR-LEV (TTR Level)''
2. Resolve any
''TONE-PT (Tone Generator)''
3. If neither condition exists, retry the test at 1-minute intervals a maximum
of five times.
1. If there are no conference calls, retry the command at 1-minute intervals
a maximum of five times.
1. If this result occurs repeatedly, reset the circuit pack, if the other ports are
not in use. Reset the circuit pack by issuing the busyout board PCSSpp
and the reset board PCSSpp commands, followed by the release board
PCSS command.
2. If this result occurs again, replace the circuit pack.
1. Retry the command at 1-minute intervals a maximum of 5 times.
to diagnose any active TDM Bus
errors in the Error Log.
errors in the Error Log.