Avaya DEFINITY Server CSI Maintenance Manual page 1672

Table of Contents

Advertisement

Maintenance Objects
2. If the 2305 errors persist:
3. For Port Networks with more than one Tone-Clock circuit pack,
4. If the problem is still not cleared, and the Tone-Clock circuit pack
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the SAKI Reset Test for example, you may also clear
errors generated from other tests in the testing sequence.
Order of Investigation
SAKI Reset Test (#53) (a)
Clock Health Test (#46) (b)
Control Channel Looparound Test (#52) (a)
Tone Generator Crosstalk Test (#90) (c)
Tone Generator Transmission Test (#40) (c)
Tone Generator Audit/Update Test (#41) (c)
TDM Bus Clock Circuit Status Inquiry Test
(#148)
TDM Bus Clock PPM Inquiry Test (#150)
TDM Bus Clock Parameter Update Test
(#151)
Board Type Check Test (#574)
1.
D = Destructive; ND = Nondestructive
1672
Issue 5 October 2002
a. Execute the test synchronization r 10 command and check
to see if new 2305 errors were reported.
If no new instances of the 2305 errors were logged for either test,
then enter test tone-clock PC long clear to clear the TDM-CLK
errors and the procedure is complete.
interchange Tone-Clocks with the set tone-clock PC, then run test
synchronization r 10, and check to see if new 2305 errors are
reported against the new Tone-Clock circuit pack. If not, replace the
Tone-Clock circuit pack. If this clears the error, the problem has
been resolved.
reported in the error log has not been replaced up to now, replace it.
Short Test
Sequence
Long Test
Reset Board
Sequence
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
Sequence
D/ND
D
ND
ND
ND
ND
ND
ND
ND
ND
ND