Avaya DEFINITY Server CSI Maintenance Manual page 1726

Table of Contents

Advertisement

Maintenance Objects
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the SAKI
Sanity Test, for example, you may also clear errors generated from other tests in
the testing sequence.
Use the list configuration control command to find the Tone-Clock Circuit Pack
Code of the system. Look for the Short and Long Test Sequences according to the
Tone-Clock Circuit Pack Code.
Table 509. System Technician-Demanded Tests: TONE-BD (TN756 only)
Order of Investigation
SAKI Sanity Test (#53) (a)
Clock Health Inquiry Test (#46)
Control Channel Loop Around Test (#52) (a)
Tone Detection Verification Test (#42) (b)
Tone Detection Audit/Update Test (#43) (b)
Tone Generator Crosstalk Test (#90) (b)
Tone Generator Transmission Test (#40)
(b)
Tone Generator Audit/Update (#41) (b)
1.
D = Destructive, ND = Non-destructive
Notes:
a. Refer to XXX-BD (Common Port Circuit Pack) documentation for
descriptions of these tests.
b. Refer to TONE-PT (Tone Generator) documentation for descriptions of
these tests.
1726
Issue 5 October 2002
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
D/ND
D
ND
ND
ND
ND
ND
ND
ND

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents