Avaya DEFINITY Server CSI Maintenance Manual page 1226

Table of Contents

Advertisement

Table 279. TEST #1386 CLAN Ethernet Status Test
Error
Test
Code
Result
1125
ABORT
2000
ABORT
2100
ABORT
2500
ABORT
FAIL
PASS
1226
Issue 5 October 2002
Description/ Recommendation
Ethernet Link is not in service.
1. Check if the ethernet link is in-service or not. If the link is not in
service, release the link using release link n or the release port
UUCSSpp command and repeat the test. This is a normal abort.
2. If the test continues to abort after following the repair procedures,
escalate the problem.
Response to the test was not received from the CLAN TN799 circuit
pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if
the other ports on the board are not in use (Yellow LED is off).
Reset the circuit pack by issuing the busyout board UUCSS,
reset board UUCSS, and release board UUCSS commands.
2. If this result occurs again, replace the circuit pack.
The necessary system resources to execute the test could not be
allocated.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 3 times
The CLAN ethernet port corresponding to the near-end address of the
SIG-GRP that is OOS has failed. All sessions are down.
1. Execute test port UUCSSpp long and verify the result of the
H.323 Signaling Group Ping Test (#1387). If the test continues to
fail, escalate the problem. If the test passes wait for the sessions
to come up.
The CLAN ethernet port corresponding to the near-end address of the
SIG-GRP that is in-service has passed this test. All sessions on the
ethernet link are up.
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF