Maintenance Objects
Table 406. TEST #1281 TCP/IP Ping Test — Continued
Error
Test
Code
Result
1125
ABORT
2000
ABORT
2012
ABORT
2100
ABORT
2500
ABORT
1003
FAIL
1504
Issue 5 October 2002
Description/ Recommendation
PPP link not in service.
1. Verify whether ppp link is in service (status port UUCSSpp or status
link n).
2. If the ppp link is not in service, release the link (release link n or
release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
Response to the test was not received from the CLAN circuit pack within the
allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the
other ports on the board are not in use (Yellow LED is off). Reset the
circuit pack (busyout board UUCSS, reset board UUCSS, and
release board UUCSS).
2. If this result occurs again, replace the circuit pack.
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Ping to the destination failed due to on-board problem.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
3. If the problem persists, re-administer the PPP connection through a
different PPP port, if available.
4. If the problem still persists, or if there are no other available PPP ports,
replace the circuit pack.