Maintenance Objects
Table 442. TEST #17 Station (Digital) Audits Test
Error
Test
Code
Result
Description/ Recommendation
1
ABORT
Switchhook audit timed out.
2
ABORT
ID request fails, health bit returned from voice terminal is bad.
3
ABORT
The EPF has detected an overcurrent condition.
4
ABORT
Internal system error
5
ABORT
Ringer update aborted due to station being in ready-for-service or
out-of-service state.
6
ABORT
This port may have been busied out by a system technician.
1000
ABORT
System resources required for this test are not available.
1566
Issue 5 October 2002
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
1. Use test UUCSSpp long. If Test #11 passes, then the EPF
condition was cleared. Rerun the Short Test Sequence. If Test #11
does not pass, follow the repair procedures described for Test #11.
2. Look for Error Type 769 logged against RDIG-STA and follow the
procedures in the associated footnote. If any additional problems
are found, rerun the test.
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1. Look in the Error Log for Error Type 18 (port busied out) for this
port. If this error is present, release the port using the release
station command.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page