Avaya DEFINITY Server CSI Maintenance Manual page 1404

Table of Contents

Advertisement

Maintenance Objects
Table 367. TEST #1122/1123 MMI Synchronization Status Test — Continued
Error
Test
Code
Result
FAIL
The MMI circuit pack is out of MMI synchronization. Run the long option of the
test board command.
1100
PASS
The MMI circuit pack is providing the synchronization correctly. This MMI
circuit pack is designated as the Master Sync source.
1101
PASS
The MMI circuit pack is listening to the synchronization signal correctly.
Control Channel Looparound Test (#52)
Refer to the repair procedure described in the XXX-BD (Common Port Circuit
Pack) maintenance documentation as Control Channel Looparound Test (#52).
SAKI Sanity Test (#53)
Refer to the repair procedure described in the XXX-BD (Common Port Circuit
Pack) maintenance documentation as SAKI Sanity Test (#53).
1404
Issue 5 October 2002
Description/Recommendation
1. Wait up to 5 minutes, and then reset the circuit pack with these
commands: busyout board PCSS, then reset board PCSS, followed by
release board PCSS.
2. Rerun the test; if the same result occurs again, replace the circuit pack.
Continued on next page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents