Maintenance Objects
Table 103. ATM Board Framer Looparound Test (#1260)
Error
Test
Code
Result
Description/Recommendation
1002
ABORT
Time slots could not be allocated. Traffic could be heavy or time slots could be
out-of-service.
Run display errors, and perform repairs associated with TDM-BUS errors.
Retry the command up to 3 times at 1-minute intervals.
1003
ABORT
Tone receiver could not be allocated.
Run display errors, and perform the repairs associated with TTR-LEV and
TONE-PT errors.
The test cannot run unless there is at least one Tone Detector available on the
network that holds the ATM-TRK circuit pack.
Retry the command up to 3 times at 1-minute intervals.
1015
ABORT
ATM-TRK circuit pack not busied out
Busyout the ATM circuit pack.
Rerun the command.
1033
ABORT
ATM-TRK circuit pack not found
See if the switch can see the circuit pack. Run status Trunk Group.
Retry the command.
1139
ABORT
Major alarm on the EPN packet bus
Run display alarms, and perform the repairs associated with PKT-BUS
errors.
Run display errors, and perform the repairs associated with PKT-BUS errors.
Retry the command.
1141
ABORT
Packet-interface circuit pack out of service
See PKT-INT (Packet Interface Circuit Pack).
1144
ABORT
Major alarm on the PPN packet bus
Run display alarms, and perform the repairs associated with PKT-BUS.
Run display errors, and perform the repairs associated with PKT-BUS.
Retry the command.
1394
ABORT
ATM-TRK circuit pack out of service
Run ATM Board Reset Test #1256.
2000
ABORT
Request timed out.
Retry the command up to 3 times at 1-minute intervals.