CO-TRK (CO Trunk)
Table 165. TEST #36 Port Audit Update Test — Continued
Error
Test
Code
Result
0
NO
BOARD
Transmission Test (#844-848)
This test is non-destructive.
NOTE:
Tests #844-848 are not supported on a International switch.
These tests are run by the Automatic Transmission Measurement System
(ATMS). They are not part of the long or short trunk test sequences. Instead, they
are run on demand with test analog-testcall or as part of ATMS scheduled
testing.
The test call attempts to seize a port and make a call to a terminating test line
(TTL) on the trunk's far end. Transmission performance measurements are made
and compared to administered thresholds. Errors are generated when results fall
outside of "marginal" or "unacceptable" thresholds. Detail and summary
measurement reports are obtainable with list testcalls.
555-233-119
Description/ Recommendation
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue busyout board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board. This should re-establish the linkage between the
internal ID and the port.