Avaya DEFINITY Server CSI Maintenance Manual page 1715

Table of Contents

Advertisement

TIE-TRK (Tie Trunk)
Table 506. TEST #844-848 Transmission Test — Continued
Error
Test
Code
Result
1947
ABORT
2000
ABORT
2012
ABORT
2053
ABORT
2056
ABORT
FAIL
8000
FAIL
555-233-119
Description/ Recommendation
Noise with tone self check failed.
1. Test the TN2402/TN798 circuit pack.
The test timed out while waiting for a response from the TN2402/TN798
circuit pack.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
An internal software error occurred.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
The test call could not be established, but no information on why is
available.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
An error occurred while trying to obtain results from the TN771 circuit pack.
1. Test the TN2402/TN798 circuit pack.
Measured transmission performance was in the unacceptable range as
administered on the trunk group form. Retrieve a measurement report via
the list testcalls command. Make sure that ATMS thresholds are set
properly on page 4 of the Trunk Group form. Besides the facility, test
failures can be caused by faulty test lines or switch paths. If the
measurements point to a facility problem, report the results to the trunk
vendor.
Measured transmission performance was in the marginal range as
administered on the trunk group form. This generally means that the trunk is
usable but has an undesirable amount of noise or loss. If the user does not
report unacceptable effects, it may not be necessary to take any action.
Retrieve a measurement report via the list testcalls command. Make sure
that ATMS thresholds are set properly on page 4 of the Trunk Group form.
Continued on next page
Issue 5 October 2002
1715

Hide quick links:

Advertisement

Table of Contents
loading