ISDN-TRK (DS1 ISDN Trunk)
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
interface circuit pack to assure that the trunk's translation is correct. The port audit
operation verifies the consistency of the current state of trunk kept in the DS1
interface circuit pack and in the switch software.
Table 320. TEST #36 Audit and Update Test
Error
Test
Code
Result
ABORT
1018
ABORT
2000
ABORT
2100
ABORT
FAIL
PASS
555-233-119
Description/ Recommendation
Internal system error
Maintenance is disabled on this trunk.
1. Enable maintenance by entering y in the Maintenance Tests? field
on page 2 of the change trunk-group form.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times
Test failed due to Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Trunk translation has been updated successfully. The current trunk states
kept in the DS1 interface circuit pack and switch software are consistent. If
the trunk is busied out, the test will not run, but will return PASS. To verify
that the trunk is in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is out-of-service,
continue to Step 2.
2. Enter release-trunk command to put trunk back into in-service.
3. Retry the test command.