Avaya DEFINITY Server CSI Maintenance Manual page 1641

Table of Contents

Advertisement

TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
Table 478. TEST #1242 Level 1 Status Inquiry — Continued
Error
Test
Code
Result
3
FAIL
4
FAIL
PASS
555-233-119
Description/ Recommendation
Received a status of Level 1 Deactivated; the port is out-of-service.
1. Issue the status bri-port PCSSpp command to verify that the service
state of the port is out-of-service. If the service state of the port is not
out-of-service, proceed to Step 2.
2. If the port has been placed out-of-service with the busyout port
PCSSpp command, try releasing the port by executing the release
port PCSSpp command. Then issue the test port long PCSSpp
command and review the results of Level 1 Status Inquiry test. If this
test still fails, proceed to Step 3.
3. After executing the test port long PCSSpp command, review the
results of all the tests. Follow the repair procedures for any tests that
fail. Verify repair of the problem by executing the test port PCSSpp
command and by determining that the Level 1 Status test passes.
Received a status of Level 1 Pending Activation, the NT1 has a loss of
power indicating a problem with the NT1.
1. Follow the manufacturer-recommended repair procedures for the NT1.
2. Execute the test port PCSSpp command and review the results of the
Level 1 Status Inquiry test to verify the repair.
This test indicates that Level 1 is activated or that software has taken the
port out of service.
Continued on next page