Avaya DEFINITY Server CSI Maintenance Manual page 1065

Table of Contents

Advertisement

DIOD-TRK (DIOD Trunk)
Port Audit Update Test (#36)
This test sends updates of the CO port translation for all ports on the circuit pack
which have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data includes: ground or loop start trunk, tone or rotary dialing
trunk, rotary dialing inter-digit timing, network balance R/RC, and disconnect
timing.
Table 219. TEST #36 Port Audit Update Test
Error
Test
Code
Result
ABORT
2100
ABORT
FAIL
PASS
555-233-119
Description/ Recommendation
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Could not allocate the necessary system resources to run the test.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
This test passed. Translation information was successfully updated on the
circuit pack. User-reported troubles on this port should be investigated by
using other port tests and by examining trunk or external wiring. If the trunk
is busied out, the test does not run, but returns PASS. To verify that the
trunk is in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release-trunk command to put trunk back into in-service.
3. Retry the test command.
Continued on next page
Issue 5 October 2002
1065

Hide quick links:

Advertisement

Table of Contents
loading