PKT-INT (Packet Interface)
Test #885 executes differently depending on which instance of Packet Interface is
tested:
1. Packet Interface 1 (TDM Bus-based) - No hardware is tested. Only
operational firmware is tested.
2. Packet Interface 2 (Packet Bus-based) - All three tests are executed.
Table 392. TEST #885 Private Looparound Tests
Error
Test
Code
Result
1006
ABORT
Packet Interface is in the out-of-service state so normal maintenance tests
1137
will not run on it.
1334
ABORT
The Packet Interface command queue is full. This should be a temporary
condition caused by a high rate of commands being sent to a Packet
Interface. Continued operation with a full command queue will cause a
system WARM restart that may escalate to more severe restart levels.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2500
ABORT
Internal system error.
NO
The Packet Interface is not detected as being physically present.
BOARD
555-233-119
Description/ Recommendation
1. Use the display system-parameters maintenance command to identify
which C-LAN circuit pack is administered with the Bus Bridge. Verify that
the C-LAN circuit pack is present and is not alarmed.
2. Request a Packet Interface reset using the reset
packet-interface AS command. Refer to the Packet Interface
Reset Test (#889) repair procedures for further action.
1. Retry the command at 10-second intervals, a maximum of 5
times.
1. Retry the command at 1-minute intervals, a maximum of 3 times.
1. Retry the command.
1. Reboot the system, then retry the command. If the NO BOARD
indication persists, replace the TN2402/TN798 Processor circuit
pack.
Continued on next page
Issue 5 October 2002
1475