RING-GEN (Analog Ring Generator)
Table 445. TEST #118 Analog Ring Generator Query Test
Error
Test
Code
Result
1
ABORT
1000
1001
1003
1115
2012
2100
2000
ABORT
1005
ABORT
FAIL
PASS
555-233-119
Description/ Recommendation
Could not seize the resources to run the test. Other maintenance is running
on the active tone/clock circuit pack.
1. Wait for the green LED on the active tone/clock circuit pack to go out;
(use the status port-network command to determine the Active
tone/clock circuit pack).
2. Rerun the test. If the test aborts again, refer to TDM-CLK (TDM Bus
Clock) Maintenance documentation.
Response to the request was not received within the allowable time period.
1. Look for TDM-CLK errors and alarms. Resolve all other tone/clock
problems first.
2. Rerun the test.
The tone/clock is unable to read the analog ringing voltage level when the
tone/clock is in the Processor Interface slot. This test is not available for the
Processor Port Network in this configuration.
This failure indicates that there is no ringing voltage in the carrier where the
active tone/clock circuit pack resides. Other carriers may or may not have
ringing voltage.
1. Unseat all analog circuit packs in the cabinet that contains the
Tone/Clock circuit pack and rerun the test.
2. If the test passes, then the Ring Generator is healthy and one of the
analog circuit packs is defective. Replace the analog circuit packs one
at a time, and rerun the test to determine which circuit pack is causing
the problem. When the defective analog circuit pack is found, replace it.
Rerun the test. If the test still fails, go to Step 4.
3. Replace the 650A power unit, and rerun the test. If the test still fails, go
to Step 4.
4. The tone/clock may be faulty and incorrectly reporting the level of the
ringing voltage. Replace the tone/clock and rerun the test. Refer to
''TONE-BD (Tone-Clock Circuit Pack)''
details on replacing the tone/clock circuit pack. Rerun the test.
Ringing voltage is acceptable in the cabinet containing the tone/clock circuit
pack.