Maintenance Objects
Port Audit Update Test (#36)
This test sends updates of the CO port translation for all ports on the circuit pack
that have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data includes: ground or loop start trunk, tone or rotary dialing
trunk, rotary dialing inter-digit timing, network balance R/RC, and disconnect
timing.
Table 165. TEST #36 Port Audit Update Test
Error
Test
Code
Result
ABORT
1006
ABORT
2100
ABORT
FAIL
PASS
934
Issue 5 October 2002
Description/ Recommendation
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The port has been placed out of service, perhaps by craft busyout. Use the
display port PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the service state indicates that the port is in use,
the port is unavailable for certain tests. Wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
System resources required to run this test were not available.
1. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
This test passed. Translation information was successfully updated on the
circuit pack. User-reported troubles on this port should be investigated by
using other port tests and by examining trunk or external wiring. If the trunk
is busied out, the test does not run, but returns PASS. To verify that the
trunk is in-service:
1. Use status-command to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release-trunk to put the trunk back into in-service.
3. Retry the test command.