Ranl-Sta (Remote Analog Line (Station) Port) - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

RANL-STA (Remote Analog Line (Station) Port)

RANL-STA (Remote Analog Line
(Station) Port)
MO Name (in
Alarm Log)
RANL-STA
RANL-STA
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, etc.).
A per-port instance of this maintenance object (RANL-STA) is used to maintain
the circuitry associated with a port which has been translated as analog station.
The combo blade circuit board has the capability of having two instances of this
type of maintenance object.
Failures of the neon message waiting lamp power and the common ringing
application circuitry are reported as part of common port circuit pack errors; see
errors 1281 and 1793 in the "XXX-BD (Common Port Circuit Pack)" section.
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing disturbs the customer or the terminal equipment,
disable it in the Tests field of the change station extension form. Be aware that
this action will also disable Test 35 on that station.
Error Log Entries and Test to Clear Values
Table 433. Analog Line Error Log Entries
Error
Aux
Type
Data
1
0
0
1(a)
40960
40975
40977
555-233-119
Alarm
Initial Command to
Level
Run
MIN
test port UUCSSpp l
WRN
test port UUCSSpp sh
Associated
Alarm
Test
Level
Any
Any
none
1
Full Name of MO
Remote Analog
Line Port
Remote Analog
Line Port
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp sh r 1
Continued on next page