Avaya DEFINITY Server CSI Maintenance Manual page 1515

Table of Contents

Advertisement

PR-MAINT (Maintenance Processor)
Table 412. TEST #103 MTP Analog Loop Around Test
Error
Test
Code
Result
1029
ABORT
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
1018
ABORT
1131
ABORT
10301
ABORT
10302
ABORT
10309
10303
ABORT
10310
10305
ABORT
10306
ABORT
555-233-119
Description/ Recommendation
(Refer to STBY-SPE Maintenance documentation for a description of these
error codes.)
The test has been disabled via administration.
1. To enable the test, issue the change system-parameters
maintenance command, and set the Test Remote Access Port field to
"y". If you are testing the Standby PR-MAINT, a refresh spe-standby
command must be successfully executed before you can proceed to
Step 2.
2. Rerun the test.
The INADS port is busy because the system is reporting alarms to INADS,
or because INADS is dialed into the system.
1. Wait about 10 minutes and then re-enter the command.
System software resources required for this test are not available.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
MTP did not respond to the test request.
1. Repeat test at 1-minute intervals a maximum of 5 times.
2. If only the MTP Analog Loop Around Test is aborting, escalate the
problem.
3. If all MTP tests are aborting, execute the test processor a/b long
command in order to reset MTP, and examine the results of the MTP
Reset Test (#101).
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
System could not determine if the testing of the INADS port is administered.
1. Enter change system-parameters maintenance command, and
verify the entry for the Test Remote Access Port field.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Issue 5 October 2002
1515

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents