Avaya DEFINITY Server CSI Maintenance Manual page 786

Table of Contents

Advertisement

Maintenance Objects
Table 106.
ATM Crosstalk Test (#1298)
Error
Test
Code
Result
Description/Recommendation
ABORT
Could not allocate required system resources.
Retry the command up to 5 times at 1-minute intervals.
1002
ABORT
Could not allocate time slots. Traffic could be heavy or time slots could be
out-of-service.
Identify and correct TDM-bus errors (if any) using the procedures in the
TDM-BUS (TDM Bus) maintenance object.
Repeat the test up to 5 times at 1-minute intervals.
1003
ABORT
Could not allocate a tone receiver. Too few tone detectors installed or tone
detectors out-of-service.
Identify and correct any TTR-LEV (TTR Level) errors listed in the Error Log.
Resolve any TONE-PT (Tone Generator) errors listed in the Error Log.
Retry the test up to 5 times at 1-minute intervals a maximum.
2000
ABORT
Test timed out.
2100
ABORT
Could not allocate required system resources
Retry the command 5 times at 1-minute intervals.
1962
ABORT
All TALKER DSPs are busy.
2302
ABORT
Inconsistent uplink message from the ATM-TRK circuit pack.
Retry the command up to 3 times at 1-minute intervals.
2752
ABORT
The circuit pack in this location is not a TN2305A/2306A.
1-8,
FAIL
ATM-TRK circuit pack writing on unauthorized TDM time slots. The error
None
code indicates the number of TALKER DSPs that are at fault. These DSPs
cannot be used again until this test of the ATM DSP Test (#1293) tells the
circuit pack to use them again.
Retry the command up to 3 times at 1-minute intervals.
If the failure persists, replace the circuit pack.
1-8
PASS
ATM-TRK circuit pack not talking to un-authorized time slots on the TDM bus.
The error code indicates the number of TALKER DSPs tested.
786
Issue 5 October 2002
Continued on next page