Maintenance Objects
Link Status Test (#601)
This non-destructive test determines the state of the call control signaling link for
Control LANs. If the signaling link is physically connected, the test sends a test
frame over the link and checks for a response. The test passes only if both the
signaling link is connected and the test frame is successfully transmitted.
A failure may indicate a problem with:
This circuit pack
The packet bus
The packet interface circuit pack
Table 149. TEST #601 Link Status Test
Error
Test
Code
Result
1125
ABORT
RSCL link or C-LAN board not in service.
2012
ABORT
Could not allocate the necessary system resources to run this test.
2100
ABORT
Internal system error.
2
FAIL
The RSCL control link disconnected.
3
FAIL
Received no response to RSCL control link test frame.
PASS
RSCL control link connected.
890
Issue 5 October 2002
Description/ Recommendation
1. Release the board.
2. Repeat the test.
3. Escalate if the problem persists.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the test continues to fail, execute the Packet Interface Test (#598)
(test board UUCSS) to determine if the problem is due to the circuit
pack.
3. If the Packet Interface Test (#598) fails, refer to Packet Interface Test
repair procedures.
4. If the Packet Interface Test (#598) passes, refer to Packet Control
Circuit Pack and Packet Bus repair procedures.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If test continues to fail, replace the circuit pack.
Continued on next page