Avaya DEFINITY Server CSI Maintenance Manual page 854

Table of Contents

Advertisement

Maintenance Objects
Memory Card Capacity Test (#1014)
This nondestructive test verifies that the memory card is using less than 98% of its
translation storage space.
This test runs
during periodic and schedule maintenance
on demand (test card-mem long, save translation).
Table 132. TEST #1014 Memory Card Capacity Test
Error
Test
Code
Result
112
ABORT
2012
ABORT
2106
2114
2013
ABORT
2100
2110
ABORT
PASS
854
Issue 5 October 2002
Description/ Recommendation
Memory Card Translation storage at least 98% full.
1. Inform the user of possible need to upgrade to larger flash card.
2. Replace the memory card with a larger one, or downgrade the alarm
to WARNING (set option).
3. Rerun the test.
Internal System Error
1. Retry the command at 1-minute intervals, up to 5 times.
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times
Memory card not present.
1. Insert formatted memory card into TN2401/TN794 or TN777B circuit
pack slot.
2. Retry the command at 1-minute intervals, up to 5 times.
The Memory Card Translation storage is less than 98% full.
Continued on next page
555-233-119