Maintenance Objects
Table 502. TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Test
Code
Result
1002
ABORT
1003
ABORT
1004
ABORT
1018
ABORT
2000
ABORT
2100
ABORT
1704
Issue 5 October 2002
Description/ Recommendation
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to TDM-BUS Maintenance to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
Maintenance documentation.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
(Non-TN497 circuit packs only.) The port was seized by a valid call during
the test. The test has been aborted. Use the display trunk xx command to
determine the trunk group/member number of the port. Use the status
trunk command to determine the service state of the port. If the service
state indicates that the port is in use, the port is unavailable for certain tests.
You must wait until the port is idle before retesting.
The test has been disabled via administration.
Verify that the 'Maintenance Test' field on the 'Trunk Group' form is set to
'n'. To enable the test, issue the change trunk-group x command (x
equals the number of the trunk group to be tested). Then, change the entry
in the
Maintenance Test
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
field on the form to y.
Continued on next page