Avaya DEFINITY Server CSI Maintenance Manual page 1714

Table of Contents

Advertisement

Maintenance Objects
Table 506. TEST #844-848 Transmission Test — Continued
Error
Test
Code
Result
1920
ABORT
1921
ABORT
1922
ABORT
1923
ABORT
1924
ABORT
1938
ABORT
1939
ABORT
1940
ABORT
1941
ABORT
1942
ABORT
1943
ABORT
1944
ABORT
1945
ABORT
1946
ABORT
1714
Issue 5 October 2002
Description/ Recommendation
No response from far end.
1. The problem is with the far end system; a technician at the far end
should test the test line (TN2402/TN798).
No data returned from far end.
1. The problem is with the far end system; a technician at the far end
should test the test line (TN2402/TN798).
Steady, unidentifiable tone from far end
1. See actions for error code 1905.
Broadband energy detected from far end (such as voice or announcement).
1. See actions for error code 1905.
No test tone from far end
1. See actions for error code 1905.
Near-end self test failed.
1. Test the TN2402/TN798 circuit pack.
Loss self check at 0dBm at 1004 Hz failed.
1. Test the TN2402/TN798 circuit packs.
Far end noise self check failed.
1. The problem is with the far end system; a technician at the far end
should test the test line (TN2402/TN798).
High frequency singing return loss self check failed.
1. Test the TN2402/TN798 circuit pack.
Echo return loss self check failed.
1. Test the TN2402/TN798 circuit pack.
Singing return loss self check failed.
1. Test the TN2402/TN798 circuit pack.
Loss self check at -16 dBm at 1004 Hz failed.
1. Test the TN2402/TN798 circuit pack.
Loss self check at -16 dBm at 404 Hz failed.
1. Test the TN2402/TN798 circuit pack.
Loss self check at -16 dBm at 2804 Hz failed.
1. Test the TN2402/TN798 circuit pack.
Continued on next page