Packet Interface Test; Congestion Query Test - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

Maintenance Objects

Packet Interface Test (#598)

This non-destructive test checks the packet bus interface circuitry on the CLAN
circuit pack. Test failure indicates faulty circuit pack.
Table 147. TEST #598 Packet Interface Test
Error
Test
Code
Result
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
2012
ABORT
Could not allocate the necessary system resources to run test.
2100
ABORT
Internal system error.
FAIL
Circuit pack has detected a failure of the Packet Interface Test (#598).
PASS
The Packet Interface Test (#598) passed.

Congestion Query Test (#600)

This non-destructive test queries the number of used buffers to determine if the
CLAN circuit pack is congested.
If:
Used buffers are, or are nearly,
exhausted,
The test fails,
Normal call handling resumes when the CLAN circuit pack has recovered from
congestion.
888
Issue 5 October 2002
Description/ Recommendation
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the test continues to fail, replace the circuit pack.
Then:
The test fails
The switch redirects outgoing calls to another
available CLAN, and denies new incoming calls
Continued on next page