Maintenance Objects
Error Log Entries and Test to Clear Values
Table 524. DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1(a)
0
Circuit pack removed or
SAKI Test (#53)
18(b)
0
busyout board UUCSS
23(c)
0
125(d)
none
None
3
257
65535
Control Channel Loop
Test (#52)
257(e)
Any
None
513(f)
Any
514(g)
46086
769(h)
46085
770(i)
46096
1025(e)
4363
NPE Audit Test (#50)
1281
Any
Loss of Signal Alarm
Inquiry Test (#138)
1300(j)
Any
Loss Of Signal Alarm
Inquiry Test (#138)
1301(k)
Any
Loss Of Signal Alarm
Inquiry Test (#138)
1302(l)
Any
Loss Of Signal Alarm
Inquiry Test (#138)
1303(m)
Any
Loss Of Signal Alarm
Inquiry Test (#138)
1310(n)
Any
Board Loopback Test
(#1209)
1311(o)
Any
Equipment Loopback
Test (#1210)
1312(p)
Any
Repeater Loopback Test
(#1211)
1313(q)
Any
CPE Loopback Jack
Test (#1212)
1766
Issue 5 October 2002
Associated Test
Any
MIN/WRN
WARNING
WARNING
MIN/WRN
MINOR
MIN/WRN
MIN/WRN
MIN/WRN
MIN/WRN
MIN/WRN
WARNING
WARNING
MIN/WRN
MIN/WRN
MINOR
MIN/WRN
MIN/WRN
MIN/WRN
Alarm
On/Off
Level
Board
Any
test board UUCSS
2
ON
OFF
release board UUCSS
OFF
add ds1 UUCSS
3
ON
ON
test board UUCSS l r 20
3
ON
3
ON
3
ON
3
ON
3
OFF
test board UUCSS
OFF
test board UUCSS
OFF
test board UUCSS
3
OFF
test board UUCSS
3
ON
test board UUCSS
ON
test ds1-loop UUCSS
ds1/csu-loopback-tests
3
OFF
test ds1-loop UUCSS
ds1/csu-loopback-tests
3
OFF
test ds1-loop UUCSS
ds1/csu-loopback-tests
3
OFF
test ds1-loop UUCSS
end-loopback/span-test
Test to Clear Value
Continued on next page