Avaya DEFINITY Server CSI Maintenance Manual page 1052

Table of Contents

Advertisement

Table 211. TEST #7 Conference Circuit Test
Error
Test
Code
Result
ABORT
1000
ABORT
1004
ABORT
1018
ABORT
1020
ABORT
2000
ABORT
2100
ABORT
2053
ABORT
FAIL
PASS
1052
Issue 5 October 2002
Description/ Recommendation
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test are not available. The port may
be in use on a valid call. Use the status station or status trunk command
to determine when the port is available for testing.
The port has been seized by a user for a valid call. Use the status station
or status trunk command to determine when the port is available for
testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Test disabled via administration. This only applies to analog stations.
1. To enable test, set the Test field on the station administration screen for
the particular analog station being tested to "y." Use the change
station extension command.
The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the previously existing error.
Response to the test request was not received within the allowable time
period.
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
At least one of the following errors is found on the DS1 circuit pack:
1281—Loss of signal
1793—Blue Alarm
2049—Red Alarm
2305—Yellow Alarm
1537—Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Replace the circuit pack.
The port can correctly conference multiple connections. User-reported
troubles on this port should be investigated by using other port tests and by
examining station, trunk, or external wiring.
Continued on next page