TIE-TRK (Tie Trunk)
Table 504. Seizure Tests (#73, #747, #73) — Continued
Error
Test
Code
Result
1040
ABORT
2000
ABORT
2100
ABORT
3
FAIL
PASS
0
NO
BOARD
555-233-119
Description/ Recommendation
(Non-TN497 circuit packs only.) This test is not performed for trunk ports
administered as access endpoints.
1. Verify this port is an access endpoint by using the display port
command.
2. If the port has been administered as an access endpoint, this test
should abort.
Seizure message is not received back within 10 seconds.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, check the far-end PBX to ensure a
translation match at both ends.
3. Check the facility.
Could not allocate the necessary system resources to run the test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
(TN439 circuit packs only.) No dial tone detected from the other end.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, check the far-end PBX to ensure a
translation match at both ends.
3. Check the facility.
The relevant seizure test passes. This port is functioning properly.
1. If users are reporting troubles, examine loop connections to the port,
wiring, and stations.
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Continued on next page
Issue 5 October 2002
1709