Station Lamp Updates Test (#16)
This test lights all lamps on the terminal as specified. The lamp updates will run
only if the station is in-service. The status of the station is checked and the lamp
updates are blocked from taking place if the station is not in the in-service state.
This test does not affect the status of the Message Waiting lamp.
Table 251. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Test
Code
Result
ABORT
1
ABORT
3
ABORT
1000
ABORT
1392
ABORT
FAIL
1160
Issue 5 October 2002
Description/ Recommendation
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
System technician may have busied out the port.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, then release the port with the release station
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
Station may be in ready-for-service or out-of-service state.
1. Use the status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test are not available. The port is busy
with a valid call. Use display port PCSSpp to determine the station
extension or attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain tests.
Wait until the port is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
This is currently a TTI port, and the test cannot execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a t for the port).
2. If either list config or display port indicates that the port is not a TTI
port, escalate the problem. If both commands indicate that the port is a
TTI port, the abort is correct, and no action is necessary.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
555-233-119