Avaya DEFINITY Server CSI Maintenance Manual page 1383

Table of Contents

Advertisement

MEDPRO (Media Processor MAPD Circuit Pack)
Table 355. TEST #1379 Ping Test
Error
Test
Code
Result
1, 2
ABORT
7
ABORT
2000
ABORT
2012
ABORT
2100
ABORT
2500
ABORT
2801
ABORT
2802
ABORT
2805
FAIL
2807
ABORT
555-233-119
Description/ Recommendation
Internal Error.
1. Retry the command at 1-minute intervals a maximum of 3 times.
Destination unreachable.
1. Verify that at least one destination reachable through this port is
up.
2. Repeat the test.
3. If the test still aborts, escalate the problem.
Response to the test was not received from the Media Processor
circuit pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack.
Reset the circuit pack by issuing the busyout board UUCSS and
the reset board UUCSS commands.
2. If this result occurs again, replace the circuit pack.
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 3 times.
The necessary system resources to execute the test could not be
allocated.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 3 times.
No IP address defined. Verify IP Interfaces translations and retest.
Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
The number of pings received did not match the number sent
(normally one ping sent). This means that no ping responses were
received from the gateway defined on the ip-interfaces form for the
Media Processor.
1. Retry the command at 1-minute intervals a maximum of 3 times.
The board is administered, but not enabled in the change
ip-interfaces form.
Continued on next page