CO-DS1 (DS1 CO Trunk)
Table 156. TEST #7 Conference Circuit Test — Continued
Error
Test
Code
Result
PASS
0
NO
BOARD
555-233-119
Description/ Recommendation
The port can correctly conference multiple connections. User-reported
troubles on this port should be investigated by using other port tests and by
examining station, trunk, or external wiring.
The test could not relate the internal ID to the port (no board).
This result could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, an insane board is inserted, or the board is
hyperactive (see note below).
1. Check to ensure that the board translations are correct. Use list
config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long.
This should re-establish the linkage between the internal ID and the port. If
this is not the case, dispatch to check to ensure that there is a valid board
inserted.
NOTE:
Hyperactivity causes some special problems with the sequence
suggested above.If the ports are translated after issuing the list
config command but the
board (when there really is a board), busyout board and release
busy board will not work (even though reset board works). The
software puts the hyperactive board back in service after the
hyperactivity clears.
Vintage
field reports that there is no
Continued on next page
Issue 5 October 2002
907