Avaya DEFINITY Server CSI Maintenance Manual page 908

Table of Contents

Advertisement

Maintenance Objects
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
Interface circuit pack to assure that the trunk's translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circuit pack and
in the switch software.
Table 157. TEST #36 Port Audit and Update Test
Error
Test
Code
Result
ABORT
1000
ABORT
2000
ABORT
2100
ABORT
FAIL
PASS
908
Issue 5 October 2002
Description/ Recommendation
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
The test was aborted because system resources required to run this test
were not available. The port may be busy with a valid call. Issue display
port PCSSpp to determine the trunk group/member number of the port.
Use status trunk to determine the service state of the port. If the service
state indicates that the port is in use, the port is unavailable for certain tests.
Wait until the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
Test failed due to internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Trunk translation has been updated successfully. The current trunk states
kept in the DS1 Interface circuit pack and switch software are consistent. If
the trunk is busied out, the test does not run, but returns to PASS. To verify
that the trunk is in-service:
1. Use status trunk to verify that the trunk is in-service. If the trunk is
in-service, no further action is necessary. If the trunk is out-of-service,
continue to Step 2.
2. Use release-trunk command to put trunk back into in-service.
3. Retry the test command.