MMI-SYNC
If the MMI circuit pack that provides synchronization is craft busied out, it will not
affect the PN synchronization. The signal is still provided by the busied-out pack.
There is no affect on synchronization if the technician issues a release of the
busied-out MMI. Synchronization is not affected by a warm start of the system
(reset system 1). For all other restarts (reboot through cold 2), MMI
synchronization recovers during board insertion.
Error Log Entries and Test to Clear Values
Table 371. MMI-SYNC Error Log Entries
Error
Aux
Type
Data
1
Any
257
Any
1.
An MMI synchronization switch was successful. Refer to MMI-BD errors for the reason for the switch.
2.
The requested MMI synchronization switch failed. Resolve all MMI-BD alarms.
System Technician-Demanded Tests: Descriptions
and Error Codes
There are no system technician-demanded tests for MMI-SYNC.
555-233-119
Associated Test
Alarm Level
None
None
MINOR
On/Off
Board
Test to Clear Value
1
See note
2
OFF
See note
Issue 5 October 2002