RANL-STA (Remote Analog Line (Station) Port)
Table 436. TEST #48 Station Present Test — Continued
Error
Test
Code
Result
FAIL
PASS
555-233-119
Description/Recommendation
The terminal equipment is not connected to the circuit pack. Some
terminal equipment, such as modems, may fail even when
connected properly.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If
present, refer to "RING-GEN".
3. Check all of the wiring between the station equipment and the
switch. Then, run the test again.
4. If the test still fails, the set may be defective. Check the set and
replace it, if necessary.
5. Some terminal equipment could fail even when it is connected
properly. If this is the case, disable the test using the change
station extension command (enter n into the Test field). Note
that this action also disables Test #35 on this port.
The station is connected properly. This test may also pass if no
terminal equipment is connected and the terminal is located very far
from the switch. User-reported troubles on this port should be
investigated by using other port tests, by examining station wiring, or
by examining the station.
Continued on next page
Issue 5 October 2002
1553