SYS-LINK (System Links)
Table 462. SYS-LINK Error Log Entries — Continued
Error
Aux
Type
Data
1537 (g)
1793 (h)
2049 (i)
Notes:
a. Error Type 13: indicates that the link went down. The link may have gone
down or never come up. Enter command status sys-link location and
check the value of the field Faulted Path. If the value is default, then
the link never came up. If the value is present, then the link came up and
went down.
Follow the Common Procedure described above. Wait for 3 min before
checking the link state. Repeat the procedure until there are no problems
with the components.
b. Error Type 257: indicates that the link has experienced uplink flow control.
Manifest effect of this error is that the end-point may be hyperactive. The
system link is alarmed if 4 or more errors of this type are detected within 10
minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
c. Error Type 513: indicates that the link has experienced downlink flow
control. Manifest effect of this error is that some information packets from
the packet interface board have been lost. The link is reset on first
occurrence, hence, Error 1025 will also be logged. The system link is
alarmed if 2 or more errors of this type are detected within 10 minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
d. Error Type 772: indicates that the link experienced a temporary disconnect
due to excessive resets or state transitions. The effect of this error is that
the link is taken down and then brought up again. The system link is
alarmed if 2 or more errors of this type are detected within 10 minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
e. Error Type 1025: This error indicates that the link has been reset. Manifest
effect of this error is that information packets queued at the time of reset
are been lost. The system link is alarmed if 20 or more errors of this type
are detected within 10 minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
555-233-119
Alarm
Associated Test
Level
WARNING
WARNING
WARNING
On/Off
Board
Test to Clear Value
OFF
test sys-link PCSSpp l cl
OFF
test sys-link PCSSpp l cl
OFF
test sys-link PCSSpp l cl
Continued on next page
Issue 5 October 2002
1605