Avaya DEFINITY Server CSI Maintenance Manual page 1653

Table of Contents

Advertisement

TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Table 485. TEST #258 ISDN TEST Call — Continued
Error
Test
Code
Result
2074
ABORT
2075
ABORT
2100
ABORT
2104
ABORT
2201
ABORT
2202
2203
2204
2205
2206
ABORT
2208
ABORT
2209
ABORT
2210
2211
ABORT
2212
ABORT
2213
ABORT
555-233-119
Description/ Recommendation
Bit and Block Error query failed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, there may be a serious internal problem
with M/T-DIG (Maintenance/Test Digital Port). If this is the case, refer to
the M/T-DIG (Maintenance/Test Digital Port) Maintenance
documentation.
Internal System Error.
1. Follow the recommendations for ABORT code 2012.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Call dropped or could not be originated.
1. Make sure service is provisioned by the network.
2. Check the administration of the far-end test line extension on the trunk
group administration form.
3. Check the administration of the test call BCC (Bearer Capability Class)
on the trunk group administration form.
4. Try the test again.
Internal System Error.
1. Follow the recommendations for ABORT code 2012.
Could not allocate the necessary system resources to run this test.
1. Follow the recommendations for ABORT code 2100.
Internal System Error.
1. Follow the recommendations for ABORT code 2012.
Could not allocate the necessary system resources to run this test.
1. Follow the recommendations for ABORT code 2100.
Internal System Error.
1. Follow the recommendations for ABORT code 2012.
Call terminated by unexpected disconnect.
1. Wait one minute and then try again.
The call has timed-out, perhaps because of a lack of system resources.
1. Follow the recommendations for ABORT code 2035.