Avaya DEFINITY Server CSI Maintenance Manual page 917

Table of Contents

Advertisement

CO-TRK (CO Trunk)
Table 159. CO Trunk Error Log Entries — Continued
Error
Aux
Type
Data
1793
Loop Around and
Conference Test
(#33)
2049
NPE Cross Talk
Test (#6)
2561 (d)
57345
None
2817 (a)
57360
None
2817 (a)
57393
None
2817 (d)
57484
Dial Tone Test (#0)
3073 (d)
57376
None
3329 (d)
57408
None
3329 (d)
57484
Dial Tone Test (#0)
3585 (d)
57424
None
3840 (f)
8000
Analog
Transmission
(#844-848)
3841 (f)
Analog
Transmission
(#844-848)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to warning alarms based on the values used in the
set options command. If the Minor alarm is not downgraded by the set-options values, the Minor
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to Table 10-93 for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
555-233-119
Alarm
Associated Test
MAJ/MIN/
WRN
MAJ/MIN/
WRN
MAJ/MIN/
WRN
MAJ/MIN/
WRN
MINOR
On/Off
Level
Board
ON
test port PCSS l r 3
2
ON
test port PCSS l r 3
2
OFF
test port PCSS l r 1
2
OFF
test port PCSS l r 1
2
OFF
OFF
test analog testcall PCSS
pp r 2
Issue 5 October 2002
Test to Clear Value
Continued on next page
917