Avaya DEFINITY Server CSI Maintenance Manual page 1643

Table of Contents

Advertisement

TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
Slip Query Test (#1244)
This test is non-destructive. Slips occur when the transmitter and receiver are not
running at precisely the same clock rate. The Slip Alarm Inquiry Test polls the total
number of slips that have occurred on a link.
When the TN2185 circuit pack detects a slip condition, maintenance software
initiates the Slip Alarm Inquiry Test to query the slip counters on the TN2185
circuit pack and total the slip counts in the maintenance software.
If the slip count is over the threshold, a Minor alarm is raised against the TN2185
circuit pack, leaving all ports of the TN2185 circuit pack in the in-service state. If
the TN2185 circuit pack is used to supply the system synchronization source, the
MINOR alarm will initiate a synchronization source switch. See TDM-BUS and
SYNC for additional information.
Table 480. TEST #1244 Slip Alarm Inquiry Test
Error
Code
Test Result
ABORT
2000
ABORT
2100
ABORT
1 to 88
FAIL
PASS
0
NO BOARD
555-233-119
Description/ Recommendation
Internal System Error
Response to the test request was not received within the allowable time
period. If Error Type 1538 is present in the Error Log, follow the
maintenance strategy recommended for this error type.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
The circuit pack and the remote endpoint are not synchronized to the
same clock rate, which has generated the Slip alarm. The error code
equals the number of slips detected by the TN2185 circuit pack since the
last Slip Alarm Inquiry Test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the circuit pack is a TN2185, enter the list measurement ds1-log
PCSS command to read the error seconds measurement.
3. Verify that both endpoints of the DS1 link are administered using the
same signaling mode, framing mode, and line coding.
4. Check the physical connections of DS1 Interface circuit packs and
cable.
5. Replace the local DS1 Interface circuit pack and repeat the test.
6. Contact T1 Network Service to diagnose the remote DS1 endpoint.
No Slip alarm is detected on the DS1 Interface circuit pack.
The DS1 Interface circuit pack is not administered.
1. Administer the DS1 Interface circuit pack by issuing the add ds1
PCSS command.
2. Run the test again.
Continued on next page
Issue 5 October 2002
1643